• EL060

    Uses Europrofile cylinders. The lock can be opened from outside by a key and inside by a handle. The lock deadlocks automatically when the door closes. Double action latchbolt and deadbolt.
  • EL066

    For use in both exterior and interior doors. Can be used on fire- and exit doors. The lock automatically deadlocks when the door is closed. The lock can be opened by key or by the interior handle.

  • EL160

    Uses Europrofile cylinders. The lock can be opened from outside by a key and inside by a handle. This deadlock escape sash lock deadlocks automatically when the door closes. Key override at all times. Fire resistant. Tested to Mechanical resistance EN12209. Meets EN179.
  • EL166

    Usable for both interior and exterior doors. Can be used on fire and exit doors. The lock automatically deadlocks when the door is closed. The lock can be opened by key outside or by handle from inside.
  • EL266

    Usable for both interior- and exterior doors. Can be used on fire- and exit doors. The lock automatically deadlocks when the door is closed. The lock can be opened by key or by the interior handle. Lock case has microswitches for indications.

  • EL366

    For use on both interior and exterior doors. Can be used on fire and exit doors. The lock automatically deadlocks when the door is closed. The lock can be opened by key outside or by handle from inside. Lock case have microswitches for indications.
  • EL461

    EL461 is a DIN standard handle controlled singlepoint lock for profile doors. Handle controlled locks are best suited in medium traffic doors. The locks can be electrically controlled by access or remote-control systems. Handle controlled locks offer great solutions to medium traffic doors where EAC is needed.

    Handle controlled locks can be set to function as fail locked or as fail unlocked. In the fail locked setting, the lock can be opened by handle when power is on and cannot be opened by handle when power is off. In the fail unlocked setting, the electrical function is reversed.

    Handle controlled doors are typically used in interior doors of offices, storages or maintenance rooms. Handle controlled locks cannot be used with door automatics.

    Both handles of the product are electronically controlled making it unsuitable for certified exit doors.

    This product is certified according to EN14846, electric lock standard including a fire approval.

  • MP420

    Motor locks are best suited in high traffic doors. The locks can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button. The locks can be used both in exit and fire rated doors. The lock case is recommended to be used in high traffic doors of public buildings, business premises, hospitals, educational premises, shopping centres and sports stadiums.